Steca Solarix 40 Amp 48 Volt PWM Charge Controller
Manufacturer Part Number: 4401
The solar charge controllers Steca Solarix 2401 and 4401 are optimally suited for inverter systems. Inverters have to be connected directly to the battery. The Steca Solarix 2401 and 4401 combine basic solar charger functions with a 40 A high-performance charge controller. It is available as 12 V / 24 V and 48 V system. This makes the solar charge controller very cost effective.
The load current is limited to 10 A. The charging processes are based on the voltage level, which can be individually set with the help of four buttons behind the front casing.
Features
-
Hybrid controller
-
Voltage regulation
-
Automatic detection of voltage
-
PWM control
-
Multistage charging technology
-
Load disconnection depending on voltage
-
Automatic load reconnection
-
Temperature compensation
-
Common positive grounding or negative grounding on one terminal
-
Integrated self test
-
Monthly maintenance charge
Specifications
Model |
2401 |
4401
|
---|
System voltage |
12 V (24 V) |
48 V
|
Own consumption |
14 mA
|
DC Input Site
|
---|
Module current |
40 A
|
DC Output Side
|
---|
Load current |
10 A
|
End of charge voltage |
13.7 V (27.4 V) |
54.8 V
|
Boost charge voltage |
14.4 V (28.8 V) |
57.6 V
|
Equalisation charge |
14.7 V (29.4 V) |
58.8 V
|
Reconnection voltage (LVR) |
12.6 V (25.2 V) |
50.4 V
|
Deep discharge protection (LVD) |
11.1 V (22.2 V) |
44.4 V
|
Operating conditions
|
---|
Ambient temperature |
-10 °C ... +60 °C
|
Fitting and construction
|
---|
Terminal (fine / single wire) |
16 mm2 / 25 mm2 - AWG 6 / 4
|
Degree of protection |
IP 32
|
Dimensions (X x Y x Z) |
187 x 128 x 49 mm
|
Weight |
550 g |
Detailed Description
Electronic protection functions
-
Overcharge protection
-
Deep discharge protection
-
Reverse polarity protection of load, module and battery
-
Automatic electronic fuse
-
Short circuit protection of load and module
-
Overvoltage protection at module input
-
Open circuit protection without battery
-
Reverse current protection at night
-
Overtemperature and overload protection
-
Battery overvoltage shutdown
Displays
-
Text LCD display for operating parameters, fault messages, self test
Operation
-
Simple menu-driven operation
-
Programming by buttons
-
Manual load switch
Interfaces
Options
-
External temperature sensor
-
Alarm contact
Certificates
-
Compliant with European Standards (CE)
-
Made in Germany
-
Developed in Germany
-
Manufactured according to ISO 9001 and ISO 14001