Cotek > 2500 Watt 24 VDC Pure Sine Wave Inverter with Schuko Socket Type
The SD series is a pure sine wave inverter designed especially for the most demanding mobile and off-grid applications. SD series provides up to 90% of high efficiency and wide operating temperature range (from -20°C to +60°C) designed for many harsh environments.
The N+X parallel redundancy framework design can greatly improve the power system's flexibility and thus the system's volume and weight are remarkable reduced. SD series features a built-in transfer switch and synchronized operation with utility AC source. SD series can be used for N+1 (N≦14) redundancy and the ability of enlarge the capacity (Users can install maximum 15 units of inverters together in parallel in order to provide the power expansion). SD series also provides complete protection functions including Input low voltage, Overload, Short circuit, Low battery alarm, Input over voltage and over temperature.
Application
Home and office appliances, portable power equipment, vehicle, yacht and off-grid solar power systems...etc.
Specifications
Model
|
SD2500-224 (Schuko)
|
Series
|
SD2500
|
Manufacturer
|
Cotek
|
Additional Details
|
Data Sheet
|
Mechanical
Type
|
Pure Sine Wave
|
Operating Temperature Range
|
-20°C to +60°C
|
Cooling
|
Load & Thermal Control Fan
|
Dimensions (W x H x D)
|
11.146" x 5.056" x 19.527"
|
Weight
|
17.64 lbs
|
Shipping Method
|
21 lbs
|
DC Input
Input Battery Voltage
|
24 VDC
|
Max Current
|
< 1.8 A
|
AC Input
AC Output Voltage
|
200 / 220 / 230 / 240 VAC +-12.5%
|
Frequency Selectable
|
50 / 60 Hz
|
Circuit Breaker
|
20A
|
Output
Maximum Output Power
|
2500 W
|
Peak Power
|
3000 W
|
Frequency
|
50 / 60 Hz +-0.1%
|
Features
- Schuko Socket Type for International 230 VAC
- Parallel redundancy design for power expansion
- Multiple industrial applications that create 1 W / 3Ф 4W power systems
- Automatic master mechanism to eliminate single point failure and optimize reliability
- Built-in ATS and AC circuit breaker
- Optional STS module, transfer time less 4ms.
- RS-232 communication
- Input & output fully isolation
- Output voltage / power saving mode selectable by DIP switch or remote control (CR-10)
- Input Protection: Reverse Polarity (Fuse) / Under Voltage / Over Voltage
- Output Protection: Short Circuit / Overload / Over Temperature / Over Voltage