Generac PWRcell 7.6kW Single Phase 120/240Vac Grid-Tied / Battery Back-Up Inverter - UL1741-SA (Rule-21)
Manufacturer Part Number: APKE00014
7.6kW PWRcell Inverter w/ CTs and CT Adapter
Generac PWRcell: The Intelligent Solar and Storage System
Solar-plus-storage is simple with the Generac PWRcell Inverter. This bi-directional, REbus™-powered inverter offers a simple, efficient design for integrating smart batteries with solar. Ideal for self-supply, backup power, zero-export and energy cost management, the PWRcell inverter is the industry’s most feature-rich line of inverters, available in single-phase and three-phase models.
Features
- No autotransformer or battery inverter needed
- User-selectable modes
- Free system monitoring
- Single inverter for grid-tied solar with smart battery integration
- Simplified system design: No autotransformer or battery inverter needed
- User-selectable modes for backup power, self-supply, time-of-use and zero-export
- Free system monitoring included via PWRview Web Portal and Mobile App
Specifications
Model
|
APKE00014
|
Series
|
PWRcell
|
Manufacturer
|
Generac
|
Mechanical
Type
|
Grid Interactive / Peak Shaving / Battery Back-up
|
Operating Temperature Range
|
-0° C - 50° C
|
Cooling
|
Advanced Front Venting
|
Dimensions (W x H x D)
|
24.5" x 19.25" x 8"
|
Weight
|
62.7 lbs
|
Shipping Method
|
Freight
|
AC Output / Grid Tie
Continuous Power Output at 25° C
|
7600 VA
|
AC Output Voltage
|
120/240 VAC
|
AC Frequency
|
60 Hz
|
Maximum Continuous Output Current
|
32 A, RMS
|
Ground-Fault Isolation Detection
|
Included
|
Charge Battery From AC
|
Yes
|
THD (Current)
|
< 2 %
|
Typical Nighttime Power Consumption
|
< 7 Watts
|
AC Output / Battery Backup
Continuous Power Output at 25° C
|
8000 VA
|
Maximum AC Backup Power Output
|
10000 W
|
AC Backup Output Voltage
|
120/240, 1Ř VAC
|
AC Frequency
|
60 Hz
|
AC Circuit Breaker
|
50 A
|
THD (Voltage)
|
< 2 %
|
Automatic Switchover Time
|
< 1 Seconds
|
Typical Nighttime Power Consumption
|
30 Watts
|
DC Input
DC Input Voltage Range
|
360-420 VDC
|
Nominal DC Bus Voltage
|
380 VDC
|
Max Input Current
|
20 A
|
Reverse-Polarity Protection
|
Yes
|
Ground-Fault Isolation Detection
|
Yes
|
Transformerless, Ungrounded
|
Yes
|
DC Input / Battery Backup
Maximum Continuous Power
|
8000 W
|
Internal DC Distribution Breakers
|
4X 2P30A
|
DC Fuses on Plus and Minus
|
40 A
|
2-Pole Disconnection
|
Yes
|
Efficiency
Peak Efficiency
|
97 %
|
CEC Weighted Efficiency
|
96.5 %
|
Additional Features
Supported Communications Interfaces
|
CANbus, RS4854, Ethernet
|
System Monitoring
|
PWRview Web Portal and Mobile App
|
Critical Load Disconnect
|
Yes
|
Manual Inverter Bypass Switch
|
Automatic
|
Warranty
|
10 Years
|
Standard Compliance
Safety
|
UL1741 SA, CSA 22.2
|
Grid Connection Standards
|
IEEE1547, Rule 21, Rule 14H
|
Emissions
|
FCC part15 class B
|
Installation Guidelines
Battery Types Supported
|
PWRcell battery module
|
Module String Size Per PV Link Optimizer
|
2-9 PV modules
|
Maximum Recommended DC Power From PV
|
10kW (1Ř)
|
Batteries Per Inverter
|
Up to 2
|
|
|
|
|
|
|
|