Lithion Battery GridBox > 60-240kW, 200-600kWh, 480 VAC Commercial Battery Energy Storage System (BESS) - Business Battery Backup
Gridbox 10GB Battery Energy Storage System
(BESS)
is a high-energy-density product
specifically designed for Utility, Commercial &
Industrial applications. The 10GB BESS Solution
includes our Lithion Battery Modules, bidirectional
inverter, isolation transformer, thermal
management system, overcurrent protection, and
our Gridbox Control System.
An environmental control system is also built in
the container, which increases service life of the
battery system. Intelligent battery management
technology is leveraged to improve the safety of
the system and its lifespan.
Why batteries for my business?
Savings and security.
Installing a power storage system with renewable generators (solar/wind) can save your business money every day and provide security against grid failure. A battery can help offset time-of-use charges and electrical multipliers from large equipment. It also provides security in case of a power outage by backing up necessary circuits or your entire business. Most businesses rely on electricity, and many would be devastated in the event of an outage. We provide solutions for hospitals, technology businesses, factories, and many more.
Model
|
10GB-480
|
Series
|
GridBox 10GB
|
Manufacturer
|
Lithion Battery
|
Specifics
|
10GB-480-0060-0200-0078
|
10GB-480-0060-0400-0078
|
10GB-480-0120-0200-0156
|
10GB-480-0120-0400-0156
|
10GB-480-0180-0600-0234
|
10GB-480-0240-0400-0312
|
10GB-480-0240-0600-0312
|
Battery Type
|
Lithium Iron Phosphate (LiFePO4)
|
Battery DC Voltage Range
|
627.2Vdc to 795.2Vdc, 716.8Vdc Nominal
|
kWac/kVA
|
60
|
60
|
120
(limited to 100)
|
120
|
180
|
240
(limited to 200)
|
240
|
MAX/kVA
|
120
|
120
|
240
(limited to 200)
|
240
|
360
|
480
(limited to 400)
|
480
|
Max. Continuous Discharge Rate (kWac)
|
60
|
60
|
100
|
120
|
180
|
200
|
240
|
kWh
|
200
|
400
|
200
|
400
|
600
|
400
|
600
|
Overload Capacity
|
~200%,7 sec
|
Inverter Make/Model
|
Sol-Ark, 60K-3P-480V-N
Inverter
|
Inverter Quantity
|
1
|
1
|
2
|
2
|
3
|
4
|
4
|
DC Coupled PV Voltage
|
180V-1000V (MPPT 200V-850V)
|
DC Coupled PV kWdc
|
78
|
78
|
156
|
156
|
234
|
312
|
312
|
# of MPPT Circuits
|
4
|
4
|
8
|
8
|
12
|
16
|
16
|
MAX DC Current per MPPT
|
36 Amps
|
AC Information
AC Voltage
|
480Y/277V
|
# AC Phases
|
3-Phase+N & GND
|
AC Amps
|
72.2
|
72.2
|
144.4
|
144.4
|
216.6
|
288.8
|
288.8
|
UL lIsted Power Factor
|
0.8~1 leading or lagging
|
Frequency
|
60Hz(59.5Hz~60.5Hz)
|
Output THD |
≤2%
|
AC PF
|
Listed: 0.8~1 leading or lagging (Controllable)
Actual: 0.1~1 leading or lagging (Controllable)
|
Grid frequency range
|
50/60±2.5Hz
|
Isolation method
|
3 Phase 4 Line Transformer
|
General Information
Dimensions (L x W x H)
|
9.8' L x 8' W x 8.5' H
|
Weight
|
20,000 lbs
|
Degree of protection
|
IP54
|
Ambient Operating Temperature
|
-4~104 F / -20~40℃
|
Relative Humidity; Elevation
|
0 to 95%; 9,842 feet/3,000 meters
|
Runtime
|
1~6.5hrs
|
Battery Chemistry
|
Lithium Iron Phosphate (LiFePO4)
|
Battery String Cycle Life
|
80% Retention with 5,000 Cycles @ 1° C to 25° C
|
Communication Protocol
|
DNP3.0, Modbus TCP/IP or RTU (RS485), IEC61850, Web APIs
|
Certifications
|
UL1741SB /UL 9540/UL9540A, CA RULE 21 ,IEEE1547,UN38.3
|
Onboard Fire Suppression System
|
NOVEC 1230
|
Fire Alarm System
|
YES
|
Onboard Controller
|
Gridbox OS
|
External Controller for Paralleling Gridbox Required
|
YES
|
Working Clearance Around Enclosure
|
6.5ft on all sides
|
Noise Generation
|
70dB @ 4ft
|
Grid Island, Black Start Capable, Grid Forming
|
YES (with built-in 200amp transfer switch per inverter, 5ms transfer time)
|
Grid Connected Only, Grid Following
|
YES
|
Features
Inverter Battery Combo: 9.8 x 8 x 8.5 Feet
- Modular design
- Supports integration of PVsolar, BESS, and Microgrid applications both grid parallel and grid island
- Lithion Battery Modules, bi-directional
inverter, isolation transformer, thermal management system, AC main breaker and our Gridbox Control System
- Equipped with Gridbox controller (GBC) to
achieve 24/7 monitoring of the BESS
|
|
|
|
|
|
|
|
|
|
|
|
|
Frequently Asked Questions
|
|
|
|
|
|
|
|
|