Morningstar SunLight 10 Amp 12 Volt PWM Charge Controller - Includes LVD Override Protection - SL-10L-12V
 
Our Price: $99.00
Warranty: 5 Years


Free Shipping
Product Code: MORNINGSTAR-SUNLIGHT-SL-10L-12
Qty:

Description Datasheet
 

MorningStar SunSaver 10 Amp 12 Volt PWM Charge Controller

Options: LVD Override Protection
Manufacturer Part Number: SL-10L-12V

Morningstar’s advanced SunLight (SL-10L-12V) solar charge controller combines the SunSaver design with a microcontroller for automatic lighting control functions.

This technology provides:

  • Proven Reliability
  • Precise Lighting Control
  • PWM Battery Charging

The MorningStar SunLight controllers combine the features of the SunSaver controllers (including LVD) with an adjustable automatic lighting control circuit. This allows you to connect a DC light and have it come on at dusk for a set period of time or dusk-to-dawn. It's 10 position rotary switch lets you choose exactly how your DC light will operate.

Features

Three Versions Available:

  • 12 Volt: 10 and 20 amp ratings
  • 24 Volt: 10 amp rating

General

  • Microcontroller digital accuracy
  • Fully automatic operation
  • Ten field adjustable lighting control options
  • Special on/off/on functions
  • Manual test capability
  • LVD override protection
  • Detects day and night using the PV array
  • Suitable for all 12/24 Vdc lamps
  • Sealed/Flooded battery select
  • Temperature compensation
  • Parallel with a SunSaver for 40 amps solar
  • Includes SunSaver battery charging circuit

Operation

  • Rotary digital switch to select among 10 lighting options (see back)
  • Test button flashes red LED to confirm correct rotary switch selection
  • Test button turns lights on for 5 minutes (in LVD limited to 3 times)
  • LVD overrides lighting timer
  • Sunrise overrides lighting timer
  • Timer accuracy is within 2 seconds

Specifications


SL-10L-12V SL-10L-24V SL-20L-12V
System Voltage 12 Volt24 Volt12 Volt
Rated Solar Input 10 Amps10 Amps20 Amps
Rated Load 10 Amps10 Amps20 Amps
25% Current Overload 5 min
Regulation Voltage: Sealed Battery
Flooded Battery

14.1 V
14.4 V

28.2 V
28.8 V

14.1 V
14.4 V
Load Disconnect 11.7 V 23.4 V 11.7 V
LVD Reconnect 12.8 V25.6 V 12.8 V
Self-consumption 8mA 9mA8mA
Operating Temp. –40 to +85°C

LED Indicators

Green: The green LED indicator will light whenever sunlight is available for battery charging. The green LED will turn off at night. Because the SunLight uses a PWM constant voltage charging process, there is usually some amount of energy going into the battery at all times. Although the charging current falls to very low levels when the battery reaches full charge, the green LED will continue to stay ON all day. This is to indicate that the controller is working and that energy is available from the PV array for charging.

Red: The red LED is an indicator for 3 different functions:

  • Automatic low voltage load disconnect (LVD) If the battery charge state falls below the LVD setpoint, the light will be disconnected and the red LED will light. This indicates the controller has disconnected the load to protect the battery from further discharge and possible damage. The red LED will turn off when the battery recovers to about 50% of its rated capacity and the load is automatically reconnected.
  • Initial controller start-up When the SunLight is properly connected to the battery, the red LED will flash 3 times.
  • Confirm lighting control selection When the TEST button is pressed, the red LED will confirm the lighting control option selected by the rotary switch

Lighting Control

To select a lighting option, turn the rotary digital switch to the desired position. An arrow in the rotary switch will point to the selected position. This is a digital switch, so it will click into each of the ten positions:

SunLight Lighting Control

OFF Lights remain turned off
2,4,6,8,10 Hours light is turned on after sundown
3/1, 4/2, 6/2 Light is turned on after sundown, turned off during the night, and turned on again one hour (3/1) or two hours (4/2, 6/2) before sunrise
D/D Dusk-to-Dawn, light is on all night

Mechanical

  • Wire size: #10 AWG (5.2 mm2)
  • Anodized aluminum case
  • Marine rated terminals
  • Epoxy encapsulated
  • Weight: 9 oz (0.26 kg)

Detailed Description

Protections

  • Polarity Protection

    The SunLight is generally protected from reversed connections, but the system operator and other equipment will be at risk when polarities (+ and –) are reversed. Carefully check before making each connection to be certain the polarity is correct.

  • Brownout Protection

    If battery voltage sags below 8 volts for any reason (such as pressing TEST in LVD with a weak battery), the microcontroller may reset. This is to prevent a low voltage condition from causing the microcontroller to lock-up at an unattended site. Note that a brownout reset will begin a new start-up sequence for measuring night length.

Functions

  • 100% Solid State

    All power switching is done with FETs. No mechanical relays are used in the controller.

  • Battery Charge Regulation

    SunLight uses an advanced series PWM charge control for constant voltage battery charging. A true 0 to 100% PWM duty cycle is very fast and stable for positive charge control under all system conditions.

  • Day-Night Transition

    The SunLight uses the solar array to detect day and night. The transition to night requires a solar insolation level less than 2 percent. The transition back to day requires a high solar array open-circuit voltage. Both state changes require 10 minutes of continuous transition values before making the change. These constraints avoid false transitions due to lightning or dark storm clouds.

  • Measure Night Length

    The LIGHTING CONTROL options that turn the lights on again before sunrise require that the SunLight measure the length of the night. Therefore, the controller cannot turn the lights on before sunrise the first night after installation (or after reconnecting the battery). If the solar array is disconnected during service, the controller will then measure a faulty night length. Either reset the controller by reconnecting the battery, or this short “night” will be automatically corrected by the controller after 4 days of service.

  • Temperature Compensation

    A sensor next to the green LED measures ambient temperature conditions. The SunLight corrects the constant voltage setpoint –27 (or –54) mV per °C with a 25°C reference. This correction matches the battery charging to the changing electrochemical properties of the battery, and works best if the battery and controller are in a similar thermal environment.

  • Sealed / Flooded Select

    Flooded batteries require more vigorous charging to avoid stratification, and sealed batteries require precise control to avoid outgassing. The SunLight constant voltage setpoints are 14.4 volts for flooded batteries, and 14.1 volts for 12 volt sealed batteries.

  • LED Indicators

  • Low Voltage Disconnect (LVD)

    If the battery falls below 11.7 (or 23.4) volts, the load is disconnected from the battery to protect against harmful deep discharges. A one minute delay prevents load disconnects from transients. The load is automatically reconnected when the battery voltage recovers to 12.8 (or 25.6) volts.

  • Battery Disconnect

    If the battery is disconnected during the daytime, the PV array will continue to provide power to the controller. The SunLight will immediately go into PWM and provide power at a constant voltage to the load. This will continue as long as sufficient power is available from the PV array.

  • Parallel Controllers

    Morningstar controllers work very well in parallel configurations. No blocking diodes are required. The only constraint is that each controller must have an independent and separate PV subarray and load. Make sure that each controller’s rating for PV and load current is not exceeded.

  • Auxiliary Generators

    Engine generators and other sources of power may be connected directly to the battery for charging. It is not necessary to disconnect the SunLight from the battery. However, do not use the SunLight to regulate these other generators.

  • Reverse Current

    The SunLight prevents the battery from discharging through the PV array at night. There is no need to install a blocking diode for this purpose.

Warranty: Five year warranty period. Contact Morningstar for complete terms.

Average Customer Review: Average Customer Review: 5 of 5 5 of 5 Total Reviews: 2 Write a review.

Accessories
Morningstar RD-1 > Relay Driver for Tristar Controller
Our Price: $149.00

Add Free Shipping
Morningstar RD-1 - Relay Driver for Tristar Controller
MorningStar DIN-1 > DIN Rail Clips - Pack of 2 Clips
Our Price: $2.00

Add
MorningStar DIN-1 > DIN Rail Clips - Pack of 2 Clips


  0 of 0 people found the following review helpful
 
5 of 5 Very nice unit August 14, 2011
Reviewer: Eric from Hood River, OR United States  
Incredibly easy to install and use. Excellent product at the best price.

Was this review helpful to you?

  1 of 1 people found the following review helpful
 
5 of 5 sunlight control August 1, 2011
Reviewer: James Eddy from Kewadin, MI United States  
I made the mistake and ordered a look alike controller to save money. I should have gone with the sunlight control to begin with. It works great and performs wonderfully. I have it controlling a lighthouse with 1 watt LED bulb a motor that rotates the Fresnel lens. I will be buying more for other solar LED projects. Delivery was quick less than 1 week.

Was this review helpful to you?


Browse for more products in the same category as this item:

Charge Controllers > Morningstar Charge Controllers > SunLight
12 VDC
Charge Controllers > Morningstar Charge Controllers
Charge Controllers > PWM Charge Controllers
Charge Controllers
1 - 10A