Victron Energy > 3000 Watt 50A MultiPlus-II Inverter & Charger - 12V DC & 2x 120V AC

Application

Mobile or Off-Grid Applications.

Note: This product is specifically designed for integration in 50A RV applications. This model includes a two pole 50A AC Input / Output.

Specifications

Model MultiPlus-II 12/3000/120-50
(PMP122305100)
Series MultiPlus-II
Manufacturer Victron Energy

Mechanical

Type Split Phase
Operating Temperature Range -40 to +65°C (-40 -150°F) (fan assisted cooling)
Cooling Fan assisted cooling
Dimensions (H x W x D) 23" x 11" x 6"
Weight 48 lbs
Safety EN-IEC 60335-1, EN-IEC 60335-2-29, UL 458
Shipping Method Ground

MultiPlus-II 2x120V

12/3000/120-50
PowerControl & PowerAssist Yes (on L1 input)
Transfer switch 50 A
Maximum AC input current 50A (each leg)

Inverter

DC Input voltage range 9.5 – 17 V
Output when in inverter mode Output voltage: 120 VAC ± 2%
Frequency: 60 Hz ± 0,1% (1)
Cont. output power at 25°C (3) 3000 VA
Cont. output power at 25°C 2400 W
Cont. output power at 40°C 2200 W
Cont. output power at 65°C 1700 W
Maximum apparent feed-in power 2500 VA
Peak power 5500 W
Maximum efficiency 93%
Zero load power 15 W
Zero load power in AES mode 10 W
Zero load power in Search mode 4 W

Charger

AC Input Split phase: 180-280 VAC 45 – 65 Hz
Single phase: 90-140 VAC 45 – 65 Hz
Charge voltage 'absorption' 14.4 V
Charge voltage 'float' 13.8 V
Storage mode 13.2 V
Maximum battery charge current (4) 120 A
Battery temperature sensor Yes

Product Desiscription

The Victron MultiPlus-II 2 x120V (MultiPlus-II 12/3000/120-50) is the perfect one-box mobile solution for standard North American 50A 120/240VAC split-phase applications. Whether it is supplied from shore power or a generator, the MultiPlus-II 2x120V can accept and passthrough both lines of a 120/240V supply, with the capability to utilize the full 50A for charging and AC loads. When connecting to a single phase 120V supply, the L1 input of the MultiPlus-II 2x120V will accept incoming power for charging and passthrough, while combining the L1 and L2 outputs for single-phase 120V on each line.

The MultiPlus switches to inverter operation when no AC source is available. The inverter output is also 120V single phase. In inverter mode, the MultiPlus-II 2x120V internally connects both lines L1 and L2 together to provide 120VAC to loads on either output. Therefore, in all connection circumstances, both sides of a distribution panel will be supplied with 120V. However, 240VAC is only available when the MultiPlus is supplied by a split phase 120/240VAC source. This prevents heavy loads such as water heaters or 240V air conditioners from discharging the battery.

The MultiPlus-II 2x 120V has all of the expected features of our versatile inverter/charger range, including PowerControl, PowerAssist, Input Current Limit, two AC outputs, as well as parallel and 3ph configuration for larger capacity VE.Bus systems. Suitable for LiFePO4 batteries and a variety of other battery technologies.

Features

  • Multifunctional, with intelligent power management
  • Two AC Outputs
  • Virtually unlimited power thanks to parallel operation
  • Split phase options
  • On-site system configuring, monitoring and control
  • Remote configuring and monitoring
  • Input voltage range: 9.5 to 17 Volts DC
  • Output voltage: 120 Volts AC +/- 2% @ 60 Hz
  • Continuous output power (77° F): 3,000 Volt-Amps (VA)
  • Zero load power: 19 Watts; 4 Watts in Search mode
  • Maximum battery charge current: 120 Amps