Rogue Engineering 5 Amp 6/12 Volt Rhino-5 Charge Controller
LVD: No
Battery: SLA
Temp Compensation: Yes
Manufacturer Part Number: 1950-136
Rogue Engineering's "3 stage" Rhino-5 Charge controller is designed to operate with no maintenance in the most challenging industrial and recreational settings. This 5 amp controller consumes only 400 micro amps, the smallest self-consumption rate in the industry. The Rhino-5 controller provides optimal battery performance. Simple and rugged, this charger can be powered by a solar panel or an AC adapter for either on or off-grid systems.
Features
- Three stage automatic charging
- Linear Charging
- Urethane encapsulation
- Testing and reliability
- Convenient
- Rated for hazardous locations
Specifications
Product |
Voltage |
Max Current |
LVD |
Battery |
Temp Compensation |
1950-136 |
6/12 VDC |
5 Amp |
No |
SLA |
Yes |
1950-143 |
12 VDC |
5 Amp |
Yes |
SLA |
Yes |
1950-210 |
12 VDC |
5 Amp |
Yes |
Flooded |
Yes |
1950-144 |
24 VDC |
5 Amp |
No |
SLA |
Yes |
1950-145 |
24 VDC |
5 Amp |
Yes |
SLA |
Yes |
1950-146 |
24 VDC |
5 Amp |
No |
Flooded |
Yes |
1950-211 |
24 VDC |
5 Amp |
Yes |
Flooded |
Yes |
1950-147 |
6/12 VDC |
5 Amp |
No |
Flooded |
Yes |
1950-211 |
24 VDC |
5 Amp |
Yes |
Flooded |
Yes |
1950-147 |
6/12 VDC |
5 Amp |
No |
SLA |
No |
1950-148 |
24 VDC |
5 Amp |
No |
SLA |
No |
1950-149 |
6/12 VDC |
5 Amp |
No |
Flooded |
Yes |
Detailed Description
Why Rogue?
Rogue is a progessive company with an electrical engineering staff that thrives on solving problems. They believe that they are a leader in the industy of electronics and that separating themselves through the competition is best accomplished through advanced technological hardware, quality workmanship and customer service.
Why the Rhino-5 Charge Controller?
Three Stage Automatic Charging
The Rhino-5 is one of the only 5 amp chargers to feature Fast, Absorption and Float. The Rhino also switches from Fast charge to Float charge when batteries are full. Float charge continuously monitors battery to maintain a fully charged state.
Multiple versions
Rogue offers multiple versions of the Rhino-5 chargers including 6, 12 and 24 volt, LVD, SLA or Flooded Cell, and non-temperature compensated versions.
Adaptable
Output voltage automatically adjusts to compensate for the temperature of the battery.
Linear Charging
The Rhino-5's Linear Charge method provides for steady charging while decreasing self-consumption.
Urethane Encapsulation
Rogue encapsulates all of its 5 and 10 amp chargers in Urethane to ensure reliability at low temperatures and a decreased failure rate.
Testing and reliability
Each controller is fully tested and inspected, ensuring reliability.
Convenient
Pluggable connectors for quick and easy installation. Compact sinple design allows for use in hard to access locations.