Samlex 25 Amp 24 Volt Battery Charger
This Ul-listed battery charger from Samlex is a great choice for automotive, RV, marine, battery backup, and communications applications. Formerly the SEC-2415A.
Specifications:
Model
|
SEC-2425UL / SEC-2425A
|
Series
|
24V Battery Charger
|
Manufacturer
|
Samlex America
|
Mechanical
Operating Temperature
|
0° C - 40° C
|
Dimensions
|
13.03" x 9.60" x 3.82"
|
Weight
|
9 lbs
|
Shipping Method
|
Ground
|
Input
Input Voltage
|
120 VAC or 230 VAC
|
Input Frequency
|
50 Hz - 60 Hz
|
Input Current
|
10.1A @120 VAC / 5.5A @ 230 VAC
|
Output
Output Voltage
|
• Bulk “I Phase” - 27.0V ± 0.05V • Absorption “Uo Phase” - 28V / 28.8V ± 0.05V • Float “U Phase” - 27.0V ± 0.05V
|
Output Current
|
25 A
|
Documentation
Features
- Switch mode technology for high efficiency, lightweight and quiet operation
- Automatic operation for ALL Lead Acid Batteries Flooded, AGM or Gel Cell
- Can charge 2 banks of batteries simultaneously, no isolator necessary
- Can be used as a power supply or DC UPS when used in conjunction with a battery
- User Configurable AC Input voltage 120 or 230 VAC, 50 / 60 Hz
- User Selectable ( by DIP Switch) for 2 or 3 stage, rapid and safe charging of standalone and loaded Lead Acid Batteries
- “Half Power Mode” reduces maximum charging current to half the rated capacity, allows for safe charging of lower capacity batteries
- Voltmeter and Ammeter for monitoring
- Fan cooled based on output current
- Protections: Short circuit, overload, reverse battery connection and over temperature
- Optional remote LED panel with 33’ cable (model: 900-RC) for remote ON/OFF control and indication of charging status
- Includes temperature sensor to prevent under/overcharging of battery if temperature varies extensively
- Safety certified and listed to UL Standard UL-1564
- EMI Compliant to FCC Part 15(B), Class B
Detailed Description
This advanced fully automatic three-stage 25 Amp battery charger (Samlex SEC-2425UL) is ideal for charging all types of 24 Volt lead-acid batteries ( Flooded / Absorbed Glass Mat / Gel Cell) from a 120 V, 60 Hz or 230 V, 50 Hz AC source.
By means of a DIP switch setting, conversion to a two-stage algorithm is possible to charge batteries connected to a DC load (DC UPS). The unit can also be used as a DC Power Supply. Features include overload and short-circuit protection. The unit allows charging of up-to 3 separate battery banks.
Also known as:
SEC-2425UL
SEC2425UL
SEC-2425A
SEC2425A
|
|
|
|
|
|
|