Tigo Energy > Module-level PV Optimizer, Monitoring and Rapid Shutdown
Dedicated Rapid Shutdown (1:1) TS4-A-O: MLPE - Optimization, Monitoring & Rapid Shutdown
TS4-A-O Module-level PV Optimizer
The TS4-A-O (Optimization) is the advanced add-on optimization solution that brings smart module
functionality to standard PV modules for higher reliability. Improve energy efficiency by upgrading
underperforming PV systems or adding smart features to new installations.
The TS4-A-O complies with NEC 2017 and 2020 690.12 Rapid Shutdown specifications when installed on
each module and accompanied by the Tigo Access Point (TAP) and the Cloud Connect Advanced
(CCA). Module-level DC production data, as well as data from other Modbus connected devices, can
be analyzed via Tigo’s Energy Intelligence Software when connected to the cloud.
The TS4-A-O with UHD-Core technology and expanded specifications supports PV modules up to 700W,
and 15A.
Specifications
Model
|
TS4-A-O
Part # 461-00252-32
|
Series
|
Module Level Power Electronics (MLPE)
TS4
|
Manufacturer
|
Tigo Energy
|
Dimensions (W x H x D)
|
5.45" x 5.5" x 0.90"
|
Weight
|
1.15 lbs
|
Shipping Method
|
Ground
|
Electrical Data
Maximum input voltage
|
80V
|
Operating voltage range*
|
16 - 80V*
|
Maximum Cont. Current (Imax)
|
15A
|
Maximum Short Circuit Current (Isc)
|
20A
|
Maximum wattage
|
700W
|
Communication Type
|
Wireless
|
Recommended Fuse Rating
|
30 A
|
Rapid Shutdown Time Limit
|
30 secs or less**
|
Conductor AWG Range
|
10-12 AWG
|
PVRSE Controlled Conductors
|
≤30 Vdc, ≤240VA, ≤8A**
|
TAP required for module-level shutdown and CCA required for monitoring with TS4-A-O. *VMOD MAX of the connected panel = TS4-A-O V
**Limits are based on NEC 690.12 rapid shutdown requirements.
|
Connections
Cable Length (in/out)
|
4.72" / 47.24"
0.12m /1.2m (Standard Cable model)
|
Connectors
|
MC4 (standard)
|
General Data
Operating temperature range
|
-40°F to +158°F
(-40°C to +70°C)
|
Outdoor rating
|
IP68, NEMA 3R
|
Maximum altitude
|
2000m
|
Product Features
- Included Features
- Module-level optimization for increased energy yield and greater design flexibility
- Manual or automatic module-level shutdown. Complies with NEC 2017 and 2020.
- Module-level monitoring for energy production tracking and system management
- Easy Installation
Snap to standard module frame or remove clips for rack mounting
- Smart Commissioning
Configure and commission with your Android or iOS mobile device
|
|
|
|
|
|
|
|
|