Based on the proven technology of the Xantrex TR Series, the Xantrex Trace Series Inverter/Charger is an economical power conversion solution designed to provide dependable modified sine wave electricity to essential circuits in the home or business during a power outage. It can also be used in conjunction with a generator or any renewable energy source in an off-grid application. In addition to providing new features, the Trace Series improves on the key features that have made the DR Series the most robust and reliable inverter/charger line for backup power and off-grid applications.
The Xantrex TR Inverter/Chargers are an economical power conversion solution designed to provide modified sine-wave electricity to essential circuits in the home or business during a power outage. They are easy to install.
Specs |
TR1512
-120-60 |
TR2412
-120-60 |
TR1524
-120-60 |
TR2424
-120-60 |
TR3624
-120-60 |
Part Number: | 989-1000 | 989-1010 | 989-1005 | 989-1015 | 989-1020
|
Waveform |
Modified Sine Wave |
Continuous Output Power |
1500 VA |
2400 VA |
1500 VA |
2400 VA |
3600 VA |
AC output voltage (rms) |
120 Vac |
120 Vac |
120 Vac |
120 Vac |
120 Vac |
AC output frequency |
60 Hz |
60 Hz |
60 Hz |
60 Hz |
60 Hz |
Rated AC output current |
12.5 Aac |
20 Aac |
12.5 Aac |
20 Aac |
30 Aac |
Overload 10 sec rating |
3000 VA |
4800 VA |
3000 VA |
4800 VA |
7200 VA |
Short Circuit 10 sec rating |
50±5 Apk |
80±8 Apk |
50±5 Apk |
80±8 Apk |
120±12 Apk |
Adjustable load sensing range |
5 Watts minimum to 240 Watts maximum |
DC input current at no load - search mode |
0.35A |
0.35A |
0.17A |
0.17A |
0.20A |
Efficiency - peak |
> 90% |
> 92% |
> 92% |
> 93% |
> 94% |
DC input voltage range |
11.0 - 15.0 Vdc |
11.0 - 15.0 Vdc |
22.0 - 30.0 Vdc |
22.0 - 30.0 Vdc |
22.0 - 30.0 Vdc |
Rated DC input current |
157 A |
252 A |
76 A |
120 A |
186 A |
Load power factor (allowed) |
0.8 to 1.0 (leading or lagging) |
Series Operation |
Yes - Two units can be connected to produce 120/240 Vac split phase power, stacking cable included |
Bypass / Charge mode: |
AC input voltage range |
65 - 140 Vac (wide), 95 - 140 Vac (narrow) |
AC input frequency range |
55 - 64 Hz (narrow-charge & pass-through),
55 - 68 Hz (wide-charge), 41 - 68 Hz (wide pass-through) |
Built-In internal supplemental breakers |
30 Aac bypass,
20 Aac charger |
30 Aac bypass,
30 Aac charger |
30 Aac bypass,
20 Aac charger |
30 Aac bypass,
30 Aac charger |
30 Aac bypass,
30 Aac charger |
DC charger rate (adjustable) |
10 - 70 A |
14 - 100 Amps |
5 - 35 Amps |
10 - 70 Amps |
10 - 70 Amps |
AC input current at max. charge rate |
11.2 Aac |
15.8 Aac |
10.2 Aac |
19.7 Aac |
19.5 Aac |
AC input power factor |
0.88 |
0.89 |
> 0.88 |
0.92 |
0.93 |
Multi-stage charging |
Yes - bulk, absorption and float, plus user-initiated equalize (for flooded batteries only) |
Temperature compensation |
Battery temperature sensor included |
Automatic transfer relay |
30 A |
Transfer time (typical) |
< 40 ms (wide), < 20 ms (narrow) |
Environmental Specifications |
Weight |
35 lbs (16 kg) |
35 lbs (16 kg) |
45 lbs (21 kg) |
35 lbs (16 kg) |
35 lbs (16 kg) |
Shipping Weight |
50 lbs (22.7 kg) |
52 lbs (23.6 kg) |
50 lbs (22.7 kg) |
55 lbs (24.9 kg) |
55 lbs (24.9 kg) |
Dimensions -inches |
8.5" x 7.25" x 21" (216 x 184 x 546 mm) |
Shipping Dimensions (W x H x L) |
12.4 x 11.8 x 26.6” (315 x 300x 675 mm) |
Specified Temperature Range |
0 - 50° C |
Mounting |
Wall-mount (with 16” mounting centers) |